PT Series
PM Series
PS Series
MT Series
TS series
MT-LCD Series
Previous Page
WELI QR code

Power Bank-DC3 UPS 2600/5200mAH

Power Bank-Chocolate No. 2 3200mAH Input: 5V 0.65A Output:5V 1A Dimension:99x40x14mm N.W.: 72g Color: brown, white, black

Power Bank-Chocolate No.3 6600mAH Input: 5V 2A Output: 5V 1A + 2.1A Size:98x76x23mm N.W.: 240g Color: brown, white

Power Bank-Chocolate No. 4 10400mAH Input: 5V 2A Output:5V 1A +2.1A Size:117x76x23mm N.W.:240g Color: brown, white

Power Bank-Choclolate No. 6 18000mAH Input: 5V 2A Output: 5V 1A+2.1A Size: 154x76x23mm N.W.: 350g Color: brown, white

Power Bank- Pandora 6000mAH,6600mAH, 7400mAH,8400mAH,9000mAH

Power Bank-Polymer Touch 10000mAH Polymer battery & Touch power on Input:5V 1A Output: 5V 1A+2A Dimension: 130x82x15mm N.W.: 214g Color: white, pink

Time: 2014/06/03~06/07, Booth No.: B0930, B0932, B1029, B1031 Taipei Computex Hall 1

 

HOME > Line Interactive UPS (Modified Sinewave) > PT Series

PT Series

PT-500

PT-500
*PT
*3448

列印..

轉寄..

*

 

1.SELF TEST:

Self test each time switched on.

When UPS is turned on, it makes self-test to provide a reliable operation and prevent any damage caused.

BATTERY PROTECTION:

Auto self-test and discharge protection.

2. DC START CAPABILITY:

The UPS can be activated without utility power.

3. UPS POWER SUPPLIED OUTLETS:

Line-Interactive UPS+AVR

Allows 75% to 125% input voltage range-best protection for computer equipment.

With AVR function (boost & buck), UPS provides a stable power to the loads as the input voltage fluctuates.

4. ELECTRICAL PROTECTION:

Automatic cut off on short circuit or Input Circuit Breaker. If UPS is overload, this circuit breaker will trip to disconnect the unit from utility power. Then the black button will pop up, and none of the surge protection outlets will provide power. Unplug at least one piece of equipment, and reset the Circuit breaker by pressing the button back into place.

5. MODEM/NETWORK PROTECTION:

RJ45 JACK ; Simultaneous protection for network, telephone, fax & modem.

6.AUDIBLE ALARM:

Battery Back-up: slow beeping (10 seconds) Battery Low and Overload or AC Overload: Rapid beeping (1 Second)

7. INTERFACE AND SOFTWARE:

RS-232 Interface.Software For -Windows98/ME/2000/NT/XP, Novell, Linux

8.  CPU MICRO PROCESS CONTROL, USE WITH STABILITY.

9. GREEN FUNCTION:

If the battery is discharging under no load, will shut down automatically to keep the span life of battery

10. BATT FAULT: Red LED Display

 

  

PT-500  Specification

MODEL

PT-500

VA

500VA

INPUT VOLTS RANGE(On Line)

110V (80V - 140V) / 220V (160V - 280V)

INPUT FREQUENCE

60/50 ± 3HZ

(AVR) OUTPUT VOLTS RANGE

110V OUT : 100V-120V / 220V OUT : 200V-240V     

OUTPUT VOLTS ON BATTERY

220VAC ±5%

OUTPUT FREQUENCE ON BATTERY

50 / 60 ± 1HZ

BATTERY RUN TIME

5~15MIN

BATTERY  QTY  / RATING

2* 6V 4 AH

Typical BATTERY charge

RATED 4HRS TO 90% OF FULL CAPACITY

TRANSFER TIME

2~4ms

OUTLETS

USA*2 or IEC*3

AUDIBLE  ALARM

BATTERY BACK-UP :  SLOW BEEPING           ( 10 SECONDS )

BATTERY LOW OR OVERLOAD : RAPID BEEPING   ( 1 SECOND )

INDICATORS

GREEN ON-LINE LED. BACK UP GREEN LED SLASH

RED OVERLOAD : BATTERY FAILT SHOT DOWN

SOFTWARE INTAFACE

RS232

ENVIRONMENT

AMBIENT OPERATING: 0-40C, 0-95% HUMIDITY NON-CONDENSING. STORAGE: 15C ~ 45C

AUDIBLE NOISE

<45DBA (1-METER FROM SURFACE)

SURGE RATING

240 JOULE

OVERLOAD

BACK UP MODE 100% SHUT DOWN.

 IN AC MODE 110% ALARMS (NO SHUT DOWN)

ELECTRICAL PROTECTION

AUTOMATIC CUT OFF ON SHORT CIRCUIT AND INPUT CIRCUIT BREAKER.

SOFTWARE / RI45

Option

UNIT DIMENSIONS (mm)

L x W x H

62 x 278 x 190

NET WEIGHT

4.5KGS

 

WELI SCIENCE CO., LTD.
ADD:No. 5, Lane 160, Jungshing N. St., Sanchung City, Taipei, Taiwan | TEL:886-2-2995 3578 | FAX:886-2-2995 3406