MT-800-1000-1500-2000  |Line Interactive UPS|MT Series

MT-800-1000-1500-2000


Code MT-1000

CTR 1933





 

 

1.   SELF TEST:

Self test each time switched on.

When UPS is turned on, it makes self-test to provide a reliable operation and prevent any damage caused.

BATTERY PROTECTION:

Auto self-test and discharge protection.

2.   DC START CAPABILITY:

The UPS can be activated without utility power.

3.   UPS POWER SUPPLIED OUTLETS:

Line-Interactive UPS+AVR

Allows 75% to 125% input voltage range-best protection for computer equipment.

With AVR function (boost & buck), UPS provides a stable power to the loads as the input voltage fluctuates.

4.   ELECTRICAL PROTECTION:

Automatic cut off on short circuit or Input Circuit Breaker. If UPS is overload, this circuit breaker will trip to disconnect the unit from utility power. Then the black button will pop up, and none of the surge protection outlets will provide power. Unplug at least one piece of equipment, and reset the Circuit breaker by pressing the button back into place.

5.   MODEM/NETWORK PROTECTION:

RJ45 JACK ; Simultaneous protection for network, telephone, fax & modem.

6.   AUDIBLE ALARM:

Battery Back-up: slow beeping (10 seconds) Battery Low and Overload or AC Overload: Rapid beeping (1 Second)

7.   INTERFACE AND SOFTWARE:

USB Interface.

Software For MS-Windows 98/NT/ME /2000

RS-232 Interface.

Software For MS-Windows 98/NT/ME /2000, Novell, Linux

8.   CPU MICRO PROCESS CONTROL, USE WITH STABILITY.

9.   GREEN FUNCTION:

If the battery is discharging under no load, will shut down automatically to keep the span life of battery

10. BATT FAULT: Red LED Display

 

MT-800/1000/1500/2000  Specification

MODEL

MT –800M

MT – 1000M

MT – 1500

MT-2000

VA/WATTS

800VA/480W

1000VA/600W

1500VA/840W

2000VA1000W

INPUT VOLTS RANGE(On Line)

110V (80V~140V) / 220V (160V~280V)

INPUT FREQUENCE

50 OR 60 ± 3HZ

(AVR) OUTPUT VOLTS RANGE

110V OUT: 100V-120V   220V OUT: 200V-240V

OUTPUT VOLTS ON BATTERY

110VAC ±10%  /  220VAC ±10%

OUTPUT FREQUENCE ON BATTERY

50 OR 60 ± 1HZ

BATTERY RUN TIME

10 ~ 40MIN

BATTERY  QTY  / RATING

1*12V 1234w

2*12V7AH

2* 12V1234w

2*12V1234W

Typical BATTERY charge

RATED 4HRS TO 90% OF FULL CAPACITY

BATTERY PROTECTION

AUTO SELF-TEST AND DISCHARGE PROTECTION

SELF TEST

SELF TEST EACH TIME SWITCHED ON

TRANSFER TIME

2~4 ms

OUTLETS

USA*3  OR  IEC*4

AUDIBLE  ALARM

 BATTERY BACK-UP :  SLOW BEEPING (10 SECONDS)

     BATTERY LOW OR OVERLOAD : RAPID BEEPING (1 SECOND)

INDICATORS

GREEN LED ON-LINE. BACK UP SLASH

RED LED OVERLOAD: BATTERY FAILT.

INTERFACE

RS-232 or USB

ENVIRONMENT

AMBIENT OPERATING: 0-40C, 0-95% HUMIDITY NON-CONDENSING. STORAGE: 15C ~ 45C

AUDIBLE NOISE

<40DBA (1-METER FROM SURFACE)

DC START

YES

SURGE ENVEGY RATING

240 JOULES

OVERLOAD

BACK UP MODE 100% SHUT DOWN.

 IN AC MODE 110% ALARMS (NO SHUT DOWN)

ELECTRICAL PROTECTION

AUTOMATIC CUT OFF ON SHORT CIRCUIT AND INPUT CIRCUIT fuse.

MODEM / NETWORK PROTECTION

RJ45(8WIRE) ONE IN → ONE OUT OPATION FOR MODEN OR NETWORK

CONFORMANCE

APPLICABLE

SOFTWARE (SUPPEORT)

OPTION

DIMENSIONS(mm) L x W x H

310*110*170

NET WEIGHT

8.KGS

12 KGS

13KGS

15KGS

 


Add to inquiry